Series And Parallel Configuration Of Pumps

Specification Of Series And Parallel Configuration Of Pumps

  • Investigation and operating behaviour of pumps in various operating modes
  • Single pump, series or parallel pump operation, configurable via valves
  • Closed water circuit contains centrifugal pumps with drive motor and a transparent water tank
  • One pump with variable speed and one pump with fixed speed
  • Adjustment of flow resistance by a valve at outlet of the pump
  • Sensors for pressure at inlet and outlet of the pumps and flow rate
  • Microprocessor-based measuring technique

Technical Data

  • Centrifugal pumps with motors
  • Power consumption: 370W each
  • Pump with variable speed: 0...3300min-1
  • Max. flow rate: 40L/min
  • Max. head: 10m
  • Pump with fixed speed: approx. 2800min-1
  • Max. flow rate: 40L/min
  • Max. head: 10m
  • Water tank: approx. 15L

Measuring ranges

  • Pressure (inlet): -1...1bar
  • Pressure (outlet): 2x 0...5bar
  • Flow rate: 10...140L/min