Product Description
Heat Transfer In A Tubular Heat Exchanger Apparatus
Specification of Heat Transfer In A Tubular Heat Exchanger Apparatus
- Heat Transfer In A Tubular Heat Exchanger
- Hot Water Circuit With Tank, Heater, Temperature Controller And Pump
- Cold Water Circuit From Laboratory Supply
- Temperature Controller Controls The Water Inlet Temperature For The Hot Water Circuit
- Parallel Flow And Counter Flow Operation Adjustable
- Flow Rates Adjustable Using Valves
- 7 Temperature Sensors With Digital Display And Selector For Temperature Measuring Points
- Process schematic
Technical Data of Heat Transfer In A Tubular Heat Exchanger Apparatus
- Heat Exchanger
- Tubes Made Of Cu, Thermal Conductivity K: 384W/Mk
- Length: 600mm
- Mean Transfer Area: 0,013m²
- Tube diameters (t=1mm): D=8mm, D=15mm
Pump
- Max. Flow Rate: 4m³/H
- Max. Head: 4m
- Power Consumption: 70w
- Heater: 3kw, With Thermal Cut-Out
- Tank: 6,5L
Measuring Ranges
- Flow Meter: 20...250l/H
- Temperature: 0...100°C